Introduction to Hotel Acoustic Solutions

In the competitive hospitality industry where guest experience is paramount, our Popular SGS/CE Certified MDF Fire Retardant Noise Reduction Perforated Acoustic Panel Sound System provides the perfect combination of safety and serenity. As China's leading manufacturer of fire-rated acoustic solutions, we specialize in creating peaceful hotel environments that meet the strictest international safety standards while delivering exceptional sound control.


Product Technical Specifications

Material Composition

  • Core: Fire-retardant MDF (750-800kg/m³)

  • Surface: 15+ finish options

  • Perforation patterns:

    • Standard: 2-6mm holes (5-15% open area)

    • Custom: Brand-specific designs

  • Thickness options: 12mm, 15mm, 18mm, 22mm

Fire & Acoustic Performance

  • Fire rating: Class A (ASTM E84)

  • Flame spread index: <25

  • Smoke developed index: <50

  • NRC: 0.75-0.92

  • STC: 28-34

Certifications

  • SGS certified

  • CE marked

  • EN 13501-1 certified

  • BS 476 Part 6 & 7 compliant

Hotel Applications

Guest Areas

  • Guest room walls

  • Corridor ceilings

  • Elevator lobbies

  • Reception backdrops

Public Spaces

  • Restaurant partitions

  • Ballroom walls

  • Conference room dividers

  • Spa relaxation zones

Special Applications

  • Feature walls

  • Headboard panels

  • Art-integrated designs

  • Branded logo panels

Manufacturing Process

Production Stages

  1. Fire-retardant treatment

  2. Precision CNC routing

  3. Acoustic perforation

  4. Surface finishing

  5. 6-point quality inspection

Quality Control

  • Thickness variance: ±0.12mm

  • Perforation accuracy: ±0.05mm

  • Surface quality: Class AA

  • Color matching: ΔE<1.0

Global Export Specifications

Packaging System

  • Fireproof wrapping

  • Shock-absorbent corners

  • Pallet configuration: 50m² per pallet

  • Container loading:

    • 20GP: 300m²

    • 40HQ: 720m²

Documentation

  • Commercial invoice

  • Packing list

  • Fire test reports

  • Acoustic performance data

  • Installation manual

Installation Methods

Wall Installation

  1. Surface preparation

  2. Adhesive application

  3. Panel placement

  4. Final finishing

Ceiling Installation

  1. Grid system preparation

  2. Panel alignment

  3. Suspension adjustment

  4. Integrated lighting

Special Techniques

  • Curved installations

  • Seamless joints

  • Lighting integration

  • Custom edge details

Maintenance Protocol

Routine Care

  • Weekly: Dry dusting

  • Monthly: Vacuum cleaning

  • Biannually: Professional inspection

Special Maintenance

  • Smoke damage treatment

  • Impact repair

  • Surface refinishing

Pricing Structure

Sample Program

  • Sample panel: $32 (600×600mm)

  • Material kit: $90

  • Worldwide express shipping

Volume Pricing

  • 100-500m²: $45.50/m²

  • 500-2000m²: $42.80/m²

  • 2000+m²: Custom quote

Custom Projects

  • MOQ: 1000m²

  • Lead time: 30-40 days

  • Design services included

Frequently Asked Questions

Q: How do your fire ratings compare to international hotel standards?A: Our panels exceed requirements for:

  1. US (NFPA 286)

  2. EU (EN 13501-1)

  3. Middle East (UAE Fire Code)

  4. Asia (GB 8624)

Q: Can these panels be customized with hotel branding?A: Yes, we offer:

  1. Laser-cut logos

  2. Brand color matching

  3. Themed perforation patterns

  4. Integrated signage

Q: What's the lead time for European hotel projects?A: Standard production takes 30 days. Rotterdam/Hamburg shipments arrive in 35-40 days by sea. Air freight available (7-10 days) with 35% surcharge.

Q: How do these panels contribute to guest comfort?A: They enhance the guest experience by:

  1. Reducing noise transfer (STC 28-34)

  2. Minimizing reverberation (NRC 0.75-0.92)

  3. Creating visual warmth

  4. Improving sleep quality

Q: Do you provide acoustic simulation for hotel projects?A: Yes, our engineering services include:

  1. Noise mapping

  2. Material optimization

  3. Installation planning

  4. Performance validation

Q: What maintenance is required for high-traffic hotel areas?A: We recommend:

  1. Monthly surface cleaning

  2. Quarterly inspections

  3. Annual professional maintenance

  4. Immediate stain treatment

Why Hotel Chains Choose Us

  1. Safety Assurance: Certified fire protection

  2. Acoustic Excellence: Proven noise reduction

  3. Aesthetic Flexibility: Custom design options

  4. Durability: Hotel-grade construction

  5. Global Compliance: International certifications

Conclusion

Our Popular SGS/CE Certified MDF Fire Retardant Noise Reduction Perforated Acoustic Panel Sound System offers hoteliers worldwide the ideal solution for creating safe, serene environments that guests appreciate. With certified fire protection, superior acoustic performance, and customizable designs, these panels represent the premium choice for hospitality projects demanding both safety and sophistication.


Popular SGS/CE Certified MDF Fire Retardant Noise Reduction Perforated Acoustic Panel Sound System for Hotels

Hot products

Cases

Contact Us

  • service time:Monday to Friday, 9:00 AM to 6:00 PM
  • Phone:
  • Contact address:
  • Website:
  • Website Map:Website Map
  • Whatsapp:
  • Email:
  • wechat:
  • WeChat QR code:
回到顶端
message

WeChat

Telephone

Online Service